Installation
3.5.9

Establish electrical power supply

☞ Observe the voltage specifications on the rating plate.
☞ Plug the connecting cable mains plug into the socket.
☞ Route the cable such that it is not kinked, crushed or
damaged and so that it will not get in the way when
replacing the filter filling.
☞ Make sure that the device can be disconnected on all
poles from the electricity supply after installation.
The device is ready for operation.
4600947_a – 05.10.2017

3.5.10 Check and carry out commissioning

D ATTENTION!
Risk of disruptions due to moisture in the device!
If the device is moved from a cold environment into a hot
one, condensation may form inside.
☞ Wait about 2-3 hours before bringing the device into
service.
☞ Check that the mains plug is freely accessible or that
an all-pole isolating device (min. 3 mm contact gap) is
present.
☞ Check that the mains cable and the electrical connection
cable are not kinked, crushed or damaged.
☞ Ensure that air outlets are not closed or covered.
☞ With recirculated air devices: Make sure that the
ventilation slots are free.
☞ Check the correct functioning of the device.
D "4. Operation" (page 74).