8
QUICK START GUIDE
Quick Start Instruction
If power is connected to the UltraFlow
Variable Speed Pump motor, pressing any of
the following buttons referred to in the following section could
result in the motor starting. Failure to recognize this could result
in personal injury or damage to equipment.
Using the factory default schedule
The following table describes the factory default
settings for DURATION and SPEED order:
Button
Duration
(In Hours)
STEP 1
STEP 2
STEP 3
OVERRIDE
Pressing the START key will start the pump based
on the factory default schedule.
Note: If power is cycled to the pump and the
user does not press the STOP key, the pump will
automatically start and run the programmed default
schedule shown in the chart above. This feature
ensures that the pump will re-start in the event of a
power outage. The pump will start on STEP 1.
Figure 1: Duration LED
Figure 2: Speed LED
®
VS
Speed
(In RPM)
4
2600
4
2100
4
1600
2
3100
User-defined custom schedule
Note: The pump must be Stopped (Press STOP
Key) when programming the DURATION and
SPEED of the STEP 1, STEP 2, and STEP 3
keys. OVERRIDE DURATION and SPEED can
be programmed when the pump is either stopped
or running.
To set the DURATION and SPEED for STEP 1,
STEP 2, STEP 3 & OVERRIDE keys:
Press the STEP 1 key. The STEP 1 button and
DURATION setting LEDs will illuminate. The bar
graph will show default DURATION for STEP 1,
see figure 1.
1.
Press UP (+) or DOWN (-) arrows to
change the DURATION.
2.
Press the STEP 1 key again to change
the SPEED setting. The SPEED setting
LED will illuminate. The bar graph will
show default SPEED for STEP 1, see
figure 2.
3.
Press UP (+) or DOWN (-) arrows to
change the SPEED.
4.
Press any STEP or OVERRIDE key
to save the DURATION and SPEED
settings for STEP 1. To revert back to
the previously stored setting, press the
STOP key.
5.
Press STEP 2, STEP 3, or OVERRIDE
key. Repeat steps 1-4 to program the
corresponding DURATION and SPEED
for each button.
6.
Press START to run the pump based on
the programmed 24 hour schedule.
7.
To stop the pump, press the STOP
button.
NOTE: The pump can only be set to operate on a
24-hour schedule. If a user attempts to program
a schedule with a combined duration for all three
steps greater than 24 hours, the pump software
will retain the current STEP time duration only,
and will zero out the other two STEP time settings.
As an example, if STEP 1 equals eight (8) hours,
STEP 2 equals nine (9) hours, and STEP 3 equals
eight (8) hours – for a combined 25 hours – the
pump will retain the setting for the current Step
being programed and zero out the remaining two.
For details regarding the set-up of the three steps
as part of a 24-hour schedule, see page 10.
NOTE: If using external devices it is the users
responsibility to verify appropriate power and
speed conditions. Refer to proper external device
manual.