Override

The UltraFlow
VS Variable Speed Pump is equipped with an
®
OVERRIDE feature, which can be engaged to temporarily run
at higher or lower speeds ranging between 600 to 3450 RPM.
Once the OVERRIDE duration has elapsed, the pump will
automatically return to the programmed schedule.
1.
Pressing the OVERRIDE key while the pump is
running will cause the pump to start running in the
OVERRIDE mode at the programmed DURATION
and SPEED. The "active LED" for OVERRIDE will
illuminate. The DURATION and SPEED setting
LEDs along with its respective bar graph LED will
blink back and forth at three (3) second intervals.
2.
The UP (+) / DOWN (-) arrows allow the user to
configure OVER RIDE DURATION and SPEED.
These settings can be changed while the pump is
running. These settings are stored each time the
UP (+) / DOWN (-) arrows are pressed.
Note: When the OVERRIDE duration ends, the
pump resumes the 24 hour schedule at the point
in the currently programmed 24 hour schedule
where it normally would be running at that time.
The OVERRIDE duration will not affect the start or
stop times of the 24 hour schedule. For example, if
OVERRIDE runs during a period overlapping with a
later part of STEP 1 and an early part of STEP 2, the
start time of STEP 3 is not affected.
Note: Pressing/Holding OVERRIDE key for more than
three (3) seconds will cancel OVERRIDE mode.
Note: During the OVERRIDE mode, the pump will not
start with the priming sequence.
Note: It is recommended that you do not set the
OVERRIDE duration to 0 HRS. Setting the OVERRIDE
duration to 0 HRS will not allow you to change the
duration setting while the motor is running. The
motor will have to be stopped in order to change the
OVERRIDE settings if the duration is set to 0 HRS.

Schedule Advance

The Schedule Advance mode allows the user to
press the START button at one time of the day,
with the 24-hour schedule starting at a different
time of day. The pump can run in the Schedule
Advance mode (by using the OVERRIDE button)
and upon completion will begin the programmed 24
hour schedule at STEP 1 DURATION and SPEED.
The following steps should be followed to set
Schedule Advance mode:
Do not perform any maintenance on the motor while the motor is in
Schedule Advance Mode. The motor may start without warning. This
event could cause death or serious personal injury.
1.
With the pump stopped, press and hold
the START key for more than three (3)
seconds. The START LED will blink at a rate
of one second per pulse. The DURATION
setting LED and respective bar graph LED
will remain turned ON until the Schedule
Advance mode is complete.
2.
Press the UP (+) or DOWN (-) arrows to set
the desired delay time after which the 24-
hour schedule should start. The Schedule
Advance mode will automatically start after
the desired delay time is selected. The
Schedule Advance mode can be cancelled
by pressing the STOP key.
Note: The OVERRIDE
button will still function when
the Schedule Advance mode
is active. This will allow the
user to run the pump during
the period of the Schedule
Advance mode.
Note: While the pump is
in the Schedule Advance
mode, if a user presses
STEP 1, STEP 2, STEP 3 or
the START key, the system
will start the normal schedule and the Schedule Advance
mode will be canceled.
Note: While the pump is in the Schedule Advance mode,
if a user presses the STOP key, then the Schedule
Advance mode is canceled.
Note: If power is lost while the pump is in the Schedule
Advance mode, then the 24-hour schedule will
automatically start when power is restored.