Put down the tool arm and insert the stirrer basket.
Place the bucket into the lower frame in such a
way that one of its four handles snaps into the
holder provided for that. So you avoid
unintended turning of the bucket during the
mixing process.
Readjustment of the machine holder
The Automix 1801 is preset at the factory to the optimal position of the
stirring rods in the bucket.
This position can be readjusted as follows:
Electrical Connection
Prior to putting the tool into operation, check the mains voltage for
conformity with the requirements of the tool's nameplate.
Voltage variations between + 6 % and – 10 % are permissible.
The Automix 1801 tool was designed according to protection class II.
Use only extension cords with a sufficient cable cross section (min. 2.5
mm²). Too small a cross section may result in loss of power and
overheating of tool and cable.
Fix the tool tightly to the stand by means of the
4 Allen screws M8 x 20 and the appropriate
locking rings.
Loosen the hexagon nut with a jaw
wrench size 17. Adjust the hexagon
nut so that the stirring rod runs as far
as possible parallel to the border of the
bucket, but does not contact this.
Hold the screw in this position by
means of the jaw wrench and retighten
the nut. Check the correct position.
16