14. Specifications

Display ..............................................................2000 counts
Measuring rate ..................................................approx. 2 - 3 measurements/second
Measuring line length .......................................approx. 75 cm each
Measuring impedance ......................................>10 MΩ (V range)
Operating voltage .............................................9 V block battery
Operating conditions .........................................0 °C to 40 °C
Storage conditions ............................................-10 °C to +50 °C, max 75% rH, non-condensing
Operating altitude .............................................max 2000 m
Weight ..............................................................approx. 200 g
Dimensions (L x W x H) ....................................137 x 72 x 35 (mm)
Measurement category .....................................CAT III 250V
Degree of contamination ..................................2
Measurement tolerances
1
Accuracy in ± (% of reading + display error in counts (= number of smallest digits)). These accuracy readings are
valid for one year at a temperature of +23 °C (± 5 °C) and a relative humidity of less than 75% (non-condensing).
DC voltage, overload protection 250 V
Range
Accuracy
VC130-1
200 mV
2000 mV
±(0.5% + 8)
20 V
200 V
250 V
±(0.8% + 8)
AC voltage (40 - 400 Hz), overload protection 250 V, mean value detection with sinusoidal signal
Range
Accuracy
VC130-1
(5 - 100% of measurement
range)
200 V
±(1.5% + 8)
250 V
38
Resolution
0.1m V
1 mV
0.01 V
0.1 V
1 V
Resolution
0.1 V
1 V