en
Eliminating minor faults yourself
Before you call customer service:
Please check whether you can eliminate the fault yourself based on the following
information.
Customer service will charge you for advice, even if the appliance is still under
guarantee!
Fault
Temperature differs
greatly from the set
value.
Displays do not
illuminate.
The refrigerating unit
is switching on more
frequently and for
longer.
Appliance is not cooling.
Displays do not
illuminate.
Appliance is not cooling,
temperature display
lamps and interior light
are lit.
The interior light is not
The interior light is not
functioning.
functioning.
28
Possible cause
Power failure; the fuse has been
switched off; the mains plug has not
been inserted properly.
The ventilation opening is covered.
Power failure!
S The fuse has tripped.
S The mains plug has not been
inserted properly.
Showroom mode is switched on.
The LED light is defective.
Door was open too long.
Light switches off after
approx. 10 min.
Remedial action
In some cases it is adequate to
switch off the appliance for
5 minutes.
If the temperature is too high, wait
a few hours and check whether the
temperature has approached the set
value.
If the temperature is too low, check
the temperature again the next day.
Check whether the power is on,
the fuse must be switched on.
Remove obstacles.
Press main switch. Fig. 1/5
Check whether the power is on,
check the fuses.
Hold down Alarm button, Fig. 2/1,
for 10 seconds until an
acknowledgement signal sounds.
After a short time check whether
your appliance is cooling.
See chapter Light (LED)" section.
When the door is closed and
opened, the light is on again.