INSTALLATIoN

Preparation

10.2 Standard delivery

The following are delivered with the appliance:
- Storage blocks

10.3 Accessories

- 2-point room temperature controller (discharge controller)
- Booster heater
- DC Control Input assembly (DC control signal)
11. Preparation
Material losses
Ensure that the differential in potential between con-
nections L, L1 on the mains power side and the various
control signals SL, A1, A2, LF, SH, LE and LH does not
exceed 230 V.
Note
There must be continuous voltage at terminals L and N
on terminal strip X2.
Note
If the appliance is connected to an automatic charge con-
trol system (e.g. EAC 4), the charge control system for
electronic charge controllers must be set without voltage
correction.

11.1 Installation location

WARNING Burns
- Ensure that the mounting wall is resistant to tem-
peratures up to at least 85 °C and the floor is resist-
ant to temperatures up to at least 80 °C.
- Maintain the minimum clearances to adjacent ob-
jects.
Note
If the appliance is installed in rooms where flue gas, oil
or petrol vapours occur or where work involves solvents
and chemicals, the operation of the appliance can result
in long lasting odours or contamination of the appliance.
Material losses
The appliance must be installed flush against the wall.
The surface on which the appliance is installed must be level and
offer sufficient load bearing capacity. For details regarding the
appliance weight, see chapter "Specification / Data table".
f If in doubt, consult a qualified structural engineer.
f
The appliances may be installed on any conventional floor, al-
though PVC, parquet and long- or deep-pile carpets may be af-
fected by pressure and heat. In such cases, heat-resistant support
plates must be used (to be provided on site).
The stability of the appliance must be ensured by fixing it to the
wall or floor (see chapter "Installation / Installation versions").
38
| ETS 200-700 Plus
All manuals and user guides at all-guides.com

11.2 Minimum clearances

f Ensure that the hot air can escape from the appliance with-
f
12. Installation

12.1 Opening the appliance

1
1 Air discharge grille
f Undo the two quarter-turn locks on the air discharge grille
f
≥100
out obstruction.
and remove it.
≥100
www.stiebel-eltron.com