oPErATIoN

Cleaning, care and maintenance

6.3.3 Contractor access
display
description
CodE
Contractor access
Note
Some menu items are protected by a code and can only
be accessed and adjusted by a qualified contractor.
7.
Cleaning, care and maintenance
Material losses
- Never spray cleaning spray into the air slot.
- Ensure that no moisture can enter the appliance.
- If a pale brownish discolouration appears on the appliance
casing, wipe it off with a damp cloth.
- Clean the appliance when cold with ordinary cleaning prod-
ucts. Avoid abrasive or corrosive cleaning products.
7.1

Cleaning the fluff filter

Note
Clean the fluff filter behind the air intake regularly. This
will ensure trouble-free discharging of the appliance. If
a fluff filter is added, switch OFF the fan.
f Clean the fluff filter behind the air intake with a vacuum
f
cleaner.
36
| ETS 200-700 Plus
All manuals and user guides at all-guides.com
8.
Problem
The appliance does not
heat up.
Room does not get warm
enough although the ap-
pliance is hot.
The heat transfer of the
appliance is too high
even in mild weather.
The room gets too hot.
Appliance does not dis-
charge.
Window open detection
does not respond.
"Adaptive start" function
does not work as re-
quired.
The display shows "E1",
"E2" or "E3".
If you cannot remedy the fault, contact your qualified contractor.
To facilitate and speed up your request, provide the number from
the type plate (000000-0000-000000).

Troubleshooting

Cause
The charge was not set or
was set too low.
Temperature set too low
on the appliance.
Fan enabling is turned
off.
No power supply.
Overheating. High limit
safety cut-out limits
heating output.
Heat demand of the room
is higher than the appli-
ance output.
The setting at the charge
control system and/or
charge controller is in-
correct.
Appliance temperature is
set too high.
The fluff filter is clogged. See chapter "Cleaning,
Appliance does not detect
a pronounced tempera-
ture drop when venting.
(Window open detection
requires a previously sta-
ble room temperature.)
Window open detection
is not enabled.
This function is only ef-
fective in timer mode.
Severely fluctuating room
temperature or the appli-
ance learning procedure
has not been completed.
"Adaptive start" function
is not enabled.
Internal fault detected.
Note
Changes or removal of faults at the charge control system
only become apparent after renewed charging.
remedy
Set a higher charge level.
Check the selected room
temperature. Adjust if
necessary.
Switch fan enabling on.
Check the fuse/MCB and
the RCD in the domestic
distribution board.
Eliminate the cause (dirt
or obstructions at the
air intake or discharge).
Observe minimum clear-
ances.
Remedy heat losses
(Close windows and
doors. Avoid constant
venting.)
Adjust the settings.
Check the selected room
temperature. Adjust if
necessary.
care and maintenance".
Wait a while after making
settings on the appliance,
until the room tempera-
ture has fully stabilised.
Avoid obstructions to air
changes between appli-
ance and indoor air.
Stop the fan for the venti-
lation period.
Switch on window open
detection in the standard
menu.
Use the timer mode for
optimised heating con-
venience.
Wait a few days for the
behaviour to stabilise.
Switch on the "Adaptive
start" function in the
standard menu.
Notify the qualified con-
tractor.
www.stiebel-eltron.com