Operating Instructions
L4000 system
8010009/1KO6/2023-08-16
Subject to change without notice
Technical data
Category
Performance Level
13)
PFHd (mean probability
of a dangerous failure
per hour)
T
(mission time)
M
Wavelength
Aperture angle/
receiving angle
Diameter (optics)
Distance sender-
receiver
Sensor with axial optics
Sensor with radial
optics
Ambient operating
temperature
Humidity (non-
condensing)
Storage temperature
Housing material
Optics
Enclosure rating
Response time
Input signal (sender only) HIGH: Transmission inactive
Output signal (receiver
only)
Shock resistance
Rigidity
Weight (plastic/metal)
SICK AG • Industrial Safety • Germany • All rights reserved
minimum
typical
Category 4 (EN ISO 138491)
PL e (EN ISO 138491)
2.9×10
–10
20 years (EN ISO 13849)
660 nm (red)
12 mm
0 m ... 10 m
0 m ... 16 m
0 m ... 5 m
0 m ... 7 m
–20 °C
15 %
–25 °C
Plastic or nickel plated brass
Plastic
IP 67
LOW —>
HIGH: 0.4 ms
HIGH —>
LOW: 0.6 ms
LOW or open circuit: Transmission active
HIGH: Light beam interrupted
LOW: Light beam unobstructed
10 g 16 ms (IEC 60068-2-27)
5 g, 10 Hz ... 55 Hz (IEC 60068-2-6)
30/67 g
en
Chapter 9
maximum
±2.5°
+55 °C
95 %
+75 °C
103