malfunction
6. GS02 on/off cartridge
does not switch
7. GS02 on/off cartridge
does not switch
8. floor moves in loading direction
when either loading or unloading is
selected
9. floor moves in the loading
direction when loading is selected,
but does not move when unloading is
selected
10. floor does not move when loading
is selected, but does move when
unloading is selected
11. all three floor groups
simultaneously move backwards and
forwards under high pressure when
unloading is selected
12. all three floor groups move
correctly when unloading is selected,
the individual groups move slowly
whereby group 2 and 3 move
together
13. other malfunction
www.cargofloor.com
info@cargofloor.com
cause
No power
Solenoid inoperable
1. Corroded contacts
2. Solenoid defective
3. Breach in the cable
Emergency control G02 is
in the loading position, the
extreme position
Plugs are connected the
wrong way round on the
solenoids
See point 6 or point 7
Capacity of the system is
insufficient to move the
load.
Capacity of the system is
insufficient to move the
load.
-
remedy
1. Check power supply
2. Check voltage across solenoid
Activate the emergency control.
1. Clean contacts
2. Use emergency control, see
Emergency control section
3. If the loading function is not used,
then swap the solenoids for GS02
and G02; note the plugs must also
be swapped
Deactivate the emergency control.
Reverse the plugs
See point 6 or point 7.
1. Check the flow, see page 25.
See point 4d
1. Thaw
2. Remove part of the load
3. Clean the floor once the load has
been removed
See point 4d
1. Thaw
2. Remove part of the load
3. Clean the floor once the load has
been removed
Contact your body builder; make sure
you have the system number available
when you do so