In the event of the failure of the Cargo Floor system to operate (in the correct manner) when used in accordance
with the operating instructions carry out the following checks:
malfunction
1. floor does not move in either the
loading or unloading direction
2. floor does not move in either the
loading or unloading direction; the
hydraulic system is at working
pressure
3. no power supply to the control
cabinet; the lights are switched on
4. floor does not move in either the
loading or unloading direction; the
hydraulic system is at working
pressure, and power is supplied to
the control cabinet
4a. floor does not move in either the
loading or unloading direction; the
hydraulic system is at working
pressure, and power is supplied to
the control cabinet
4b. pressure relief valve on the
tractor unit is activated
4c. pressure relief valve on the semi-
trailer switches
4d. capacity of the system is
insufficient to move the load
5. floor does not move in either the
loading or unloading direction; the
hydraulic system is at working
pressure
www.cargofloor.com
info@cargofloor.com
GB
TROUBLESHOOTING
cause
No hydraulic pressure
No power supply
Break in cable, contact
points corroded, system
connected wrongly
Blocked quick-detachable
coupling – note, also the
return line!
Hydraulic oil released via
the pressure relief valve
fitted to either the tractor
unit or the system
System does not achieve
working pressure
Measure the pressure at
measurement point M1,
pressure (above) 225 bar
1 frost
2 overloaded
3 floor is dirty
Measure pressure at M1
Pressure = 0-10 bar
remedy
1. Switch on PTO / pump
2. Check quick-detachable couplings
between tractor unit and trailer;
where relevant, lock in position
1. Switch on lights
2. Switch on control cabinet
3. Measure power supply to control
cabinet
Trace the cause of the electrical
malfunction in the circuit between the
control cabinet and the trailer lighting.
See 6 and 7 also.
Check the quick-detachable couplings,
and unblock if necessary
Check whether oil is released via the
pressure relief valve fitted to either the
tractor unit or the trailer. This can be
determined from the hissing sound made
by the valve.
1. If a tipping valve is fitted, is it in the
correct position?
2. Measure the pressure at the pump,
have the pressure adjusted if
necessary.
1. Check the setting of the threaded rod
2. Capacity of the system is
insufficient to move the load.
1. Thaw
2. Remove part of the load
3. Clean the floor once the load has
been removed
1. Move threaded rod backwards and
forwards
2. GS02 on/off cartridge does not
switch
Activate the emergency control.
2012 Cargo Floor B.V. Coevorden, Holland
Versie 01/11-01-2012
Blz. 79