3. Carefully move the burner off the injector
support D.
E
4. Slowly move it to the left side. Make sure
that the burner bush stays on the burner
mouthpiece. Do not apply force to the
wire of the spark plug connector F and to
the thermocouple conductor E.
5. Release the burner injector D with a 7
mm socket spanner and replace it with a
different one.
Assemble the burner in a revers sequence.
Replace the gas type sticker near the gas
supply ramp with the one related to the new
gas type.
3.15 Adjusting the minimum gas
level on the oven burner
1. Disconnect the appliance from the
electricity.
2. Remove the knob for the oven functions.
If there is no access to the bypass screw
D
F
dismount the control panel before
adjustment start.
3. With a thin and flat screwdriver adjust the
bypass screw A.
The model determines the position of the
bypass screw A.
Changing from natural gas to liquid
gas
1. Fully tighten the bypass screw.
2. Put the knob back.
3. Connect the appliance to the electricity.
Changing from liquid gas to natural
gas
1. Unscrew approximately one turn the
bypass screw position A.
2. Put the knob for the oven functions back.
3. Connect the appliance to the electricity.
WARNING!
Put the mains plug into the mains
socket only if all parts are back into
their initial position. There is a risk of
injury.
4. Light the burner.
Refer to "Oven - Daily use" chapter.
5. Turn the knob for the oven functions on
the minimum position.
6. Remove the knob for the oven functions
again.
7. Screw on slowly the bypass screw till the
flame becomes minimum and stable.
8. Put the knob for the oven functions back.
A