Before start-up
Secure the detachable handle (Fig. I)
Click the handle [1] in on the welding unit.
Transport
Always remove the mains plug before trans-
porting.
Carry the device using the handle.
Installation
Install the device in a safe place on a horizontal,
dry surface. Ensure that the ventilation slots of the
cooling ribs are always free.
Quick-start guide
Insert the mains plug into the plug socket.
Connect the workpiece lead and electrode holder
to the connecting sockets [3] and [4].
Attention
Observe the polarity as specified by
the electrode manufacturer (see also
Electrode welding).
Clamp a stick electrode in the electrode holder.
Switch the system on at the switch [6].
Set the welding current at the rotary controller
[10].
The system is ready for welding.
3
Connecting the workpiece lead
(Fig. III)
When selecting the workplace, ensure that the
workpiece lead and ground clamp can be cor-
rectly connected.
The ground clamp must have good electrically
conductive contact with a bare metal part of the
welding bench or workpiece. It must be located in
the immediate vicinity of the welding point so that
the welding current cannot find its own way back
via machine parts, ball bearings or electrical
circuits.
Do not connect the ground clamp to the weld-
ing machine or gas cylinder as otherwise the
welding current will run through the PE conduc-
tor connections and could destroy them.
Fasten the earthing clamp securely to the weld-
ing bench or workpiece.
Connect to mains
Plug the plug into a suitable socket.
The fuse must conform with the technical
specifications.
Start-up
Before switching on, ensure that the electrode or
electrode holder is not in contact with the welding
bench, workpiece or other electrically conductive
object so that an arc is not struck unintentionally
when switching on.
Attention !
An unintentionally drawn arc can damage the elec-
trode holder, welding bench, workpiece or device.
Operating panel, displays and func-
tions (Fig. II)
Menu / ancillary parameters button [14]
Used to call the ancillary parameters.
7-segment display [7]
Indicates the selected welding current.
If ancillary parameters are selected, the code and
the set value of the ancillary parameter are dis-
played alternately.
Fault LED [8]
Lights up if the system overheats; striking an arc is
not possible.
Once the system is switched on, the LED flashes as
a self-test.
Welding current rotary controller [10]
For stepless adjustment of the welding current.
CEL electrode LED [11]
Lights up when "CEL electrode" mode is selected.
(Electrodes with cellulose coating, suitable for
vertical-down welds)
Basic electrode LED [12]
Lights up when "Electrode" mode is selected.
(Electrodes with basic coating)
TIG electrode LED [13]
Lights up when "TIG electrode" mode is selected.