Note: The base station the components are connected to must be configured as master. Further
base stations can only be paired with the master.
The pairing of base stations is done as follows:
¾ Press the syBUS button of the base station to be configured as master for three seconds in
order to start the pairing mode.
9 The LED "Master" flashes.
9 For three minutes, the pairing mode is ready to receive the pairing signal of another room
control unit.
¾ Press the syBUS button of the base station to be configured as slave two times consecutively
for one second, in order pair it with the master.
9 The paring mode ends automatically after the process has finished.
9 The LED "Master" lights up permanently at the master base station.
9 The LED "Master" flashes if the base station has been configured as slave.
¾ Repeat the process for paring another base station.
The separation of paired base stations can be performed as follows:
¾ Press the syBUS button of the base station to be separated for three seconds in order to start
the pairing mode.
9 The LED "Master" flashes.
¾ Press the syBUS pushbutton again for a duration of 10 seconds.
9 The base station restarts and the LED "Master" goes out.
4.4 Allocation of a room control unit to a heating zone (pairing)
¾ Press the rmBUS button of the base station for three seconds in order to start the pairing
mode.
9 The LED "Heating zone1" flashes.
¾ Select the desired heating zone by pressing shortly again.
9 For three minutes, the selected heating zone is ready to receive the pairing signal of a room
control unit.
¾ Activate the pairing function at the room control unit (see Room Control Unit Manual).
9 The pairing mode is left after establishing a successful allocation.
9 The LED of the heating zone previously selected will light up for 1 minute.
¾ Repeat the process for allocating more room control units.
Tip
One Room Control Unit can be allocated to various heating zones.
The allocation of several room control units to one zone is impossible.