Procedure:
1. Check whether the printed circuit board centering
bolts are present and securely in place at the
respective positions in the inverter. If PCB centering
bolts are missing, remove and reinsert the PCB
centering bolts from the defective assembly.
2. Clean the supporting surfaces in the enclosure. To do so, use the cleaning cloths included in
the delivery. Cleaning can be made easier using Isopropanol.
3. Carefully remove the assembly upwards out of the packaging. Only hold the assembly by the
handling area and ensure that the assembly has been checked (see Section 7.1, page 18).
4. Align the assembly and insert it into the inverter. Put the assembly onto the PCB centering pins.
Ensure that the PCB centering pins match the holes in the assembly.