2. Turn the selector ring for driving energy to the desired energy level.
Energy levels:
•
1 = lowest energy
•
8 = highest energy
3. Check whether the fastener was correctly driven in accordance with the operating instructions of the
fastener.
6.5
Driving fasteners
1. Position the fastening tool.
2. Hold the fastening tool perpendicular to the working surface and then press it at right angles against the
surface.
3. Press the trigger to drive the fastener.
6.6
Unloading the single-fastener tool
1. Pull the cartridge strip up and out of the fastening tool.
2. Pull the fastener out of the fastening tool.
6.7
Unloading the magazine tool
1. Pull the cartridge strip up and out of the fastening tool.
2. Pull the magazine shutter down and remove the nail strip.
6.8
Resetting the cleaning indicator
The cleaning indicator consists of 5 bars. Each bar stands for 500 fastenings.
The cleaning indicator is designed to indicate the correct cleaning intervals when the following
cartridges are used:
•
DX 6 cartridge titanium-gray
•
DX 6 cartridge, black
▶ Press the operating button at the display and hold it down for 10-12 seconds.
▶ The cleaning indicator is reset.
7
Troubleshooting
WARNING
Risk of explosion! Cartridges may fire (explode) if handled improperly.
▶ Do not use force to remove cartridges from the fastening tool or the magazine strip.
WARNING
Hazard due to hot surfaces! The fastening tool can become hot in use.
▶ Wear protective gloves.
7.1
Fastening tool jams and does not extend
DANGER
Risk of injury by unsecured fastening tool! If the fastening tool jams in the compressed state or if a
cartridge does not fire, the fastening tool might be loaded with the safety off. Unintentional triggering can
cause severe injuries.
▶ At all times, make sure that the fastening tool is not pointing toward you or anyone else.
▶ Take your finger off the trigger and do not hold your hand in front of the muzzle of the fastener guide.
▶ Keep a fastening tool with the safety off under observation at all times.
1. Keep the fastening tool pressed against the work surface for at least 10 seconds and trigger the fastening
tool again.