WARNING
For Synergic Welding Mode the machine automatically
select the proper Wire Feeding Speed for each position of
the Welding Load Voltage Switch [3]. The automatic
speed value can be adjusted in the range of the 25% by
the WFS Control Knob [5].
Burnback
Run-in WFS
Preflow Time
2-Step/4-Step
The 2-Step - 4-Step changes the function of the gun's
trigger.
2 Step trigger operation turns welding on and off in
direct response to the trigger. Welding process is
performed when the gun's trigger is pulled.
4-Step mode allows to continue welding, when the
gun's trigger is released. To stop welding, the gun's
trigger is pulled again. 4-step mode facilitates to
making long welds.
The Burnback Time is the amount of time that the weld
output continues after the wire stops feeding. It prevents
the wire from sticking in the puddle and prepares the end
of the wire for the next arc start.
Run-in WFS sets the wire feed speed from the time the
trigger is pulled until an arc is established.
Preflow Time adjusts the time that shielding gas flows
after the trigger is pulled and prior to feeding.
English
Transport & Lifting
Falling equipment can cause injury and
damage to unit.
CITOSTEP
max 45°
To safety transport and lift the machine (see the
Figure 14):
Use equipment of adequate capacity to lift and support
unit.
Always lift and support unit using both eye bolts.
Do not use one eye bolt to lift or support unit.
Lift only power source without gas cylinder, cooler and
wire feeder, or any other accessories.
Screw down an eye bolt and apply load axially in 45
degree angle in accordance to the Figure 14.
Ensure equal length of lifting lines.
Do not use handle to lift or support unit.
15
WARNING
355C
Figure 14.
English