EN
Work as Standalone Alarm Panel
When it works as a standalone alarm panel, it should be connected
with wireless sensors or wired sensors in advance, when the
intrusion is detected, it hoots and the strobe light flashes to deter
illegal intruders.
Wired Terminals
The siren has terminals for power supply and wired sensors. Just
connect the power line or wired sensors to this wired terminals.
Please make sure the positive and negative are distinguished.
-DC12V+
24-ZONE
-DC12V+ :
Power input
ZONE (normal zone
mode):
"ZONE" terminal, means it will work as a normal zone sensor, once
it is triggered in Arm or Home Arm state, alarm panel will alarm
immediately.
24-ZONE (24-hour zone mode):
with "24-ZONE" terminal, means it will work as a 24-hour zone
sensor, siren will alarm immediately once it is triggered.
ZONE
After a wired sensor is connected with
After a wired sensor is connected
Connection & Disconnection
Maximum 40 sensors can be connected to the wireless strobe siren.
Connect with Remote Control
Press Learn button for 0.5 second till a beep is heard, the siren
enters connection status.
Press any button in the remote control, the connection succeeds
when a beep is heard from siren.
Connect with Door Window Contact
Put the door window contact transmitter and magnet close in right
position.
Press Learn button for 0.5 second till a beep is heard, the siren
enters connection status. Separate the magnet from the transmitter
over 2 cm, the connection succeeds when a beep is heard from
siren.