3.4

ENERGY SAVING ADVICE

-
Always keep the filters clean (see chapter on maintenance and cleaning).
-
Keep the doors and windows closed in the air-conditioned rooms.
-
Keep sunlight out of the room by using curtains, lowering the shades or closing the shutters.
-
Do not obstruct the air flow channels (both inlet and outlet) of the unit; apart from preventing the optimal performance of
the system, this would also jeopardise correct operating and could cause irreparable damage to the unit.
3.5

DIAGNOSIS OF THE PROBLEMS

It is important for the User to distinguish between functional problems and anomalies in relation to the behaviour of the appliance
as foreseen for its normal operation. Furthermore, the most common problems may easily be solved through simple operations
on behalf of the User (See paragraph: Anomalies and solutions), while for all of the other anomalies it is necessary to contact the
Olimpia Splendid Service Centre.
WARNING: Please remember that any attempt to repair the appliance by unauthorised personnel will immediately inva-
lidate any form of guarantee.
3.5.1

Functional aspects not to be interpreted as problems

-
The compressor does not start up again immediately after a stop (it takes about three minutes to start again).
In the operating logic of the appliance a delay between a compressor stop and its successive restart has been included,
so that the compressor itself is protected against activations that are too frequent.
-
During the heating operation of the heat pump appliances, the flow of hot air may occur some minutes after activation of
the compressor.
Should the fan start at the same time as the compressor, for the first few minutes it would emit cold air into the room (and
this could bother the occupants) since the unit has not yet reached steady running conditions.
3.5.2

Troubleshooting

In case of malfunctions, check the following table.
If the problem persists after the suggested checks and controls, contact the authorised technical service.
FAULTS
The unit does not turn on
The unit does not cool or
heat adequately
38

POSSIBLE CAUSES

• No power supply
• The power switch is in "0" position
• Remote control batteries are flat
• The temperature set on the remote control is
either too high or too low (when using the hea
ting pump unit).
• The air filter has been blocked before the
respective cleaning LED was switched on.
• Indoor or outdoor air flow obstacles are present.
• The heating/cooling load has increased (for
example a door or a window was left open or
equipment that dissipates a large amount of
heat was installed in the same room);
SOLUTIONS
• Check that mains power is present (by turning on a
light for instance).
• Check if the master switch is closed or if a fuse is
burnt (in this case replace the fuse). If there is a
magnetothermal circuit breaker instead of the
master switch, check if it tripped (if it did, rearm it).
Should the problem occur again, contact the Servi
ce Center at once and do not attempt to run the
unit.
• Move the power switch to "1" position (fig. 23
ref.A).
• If the batteries are flat, you will notice that no
messages are displayed and that the unit's
reception confirmation sound is missing when you
try to issue any command to it. In this case replace
the batteries.
• Check the temperature setting on the remote
control and correct it if need be.
• Check the air filter and clean it if necessary.
• Remove anything that might clog the air flows.