ELECTRONIC CIRCUIT BOARD
RS232
socket
right-hand
ventilation
SAFETY DEVICES
• THERMO COUPLING:
located on the smoke exhaust, detects the temperature. On the
basis of the parameters set, check the ignition, working and
turn-off phases.
• AIR FLOW SENSOR:
Positioned in the suction channel, this intervenes when the
fuel air fl ow is incorrect, with consequent depression pro-
blems in the smoke circuit.
• SAFETY THERMOSTAT (150 °C):
Intervenes when the temperature within the insert is too high.
Blocks pellet loading causing the insert to turn off.
• ROOM TEMP. DETECTION PROBE:
located on the remote control. Alternatively it can be con-
nected up to the electronic board inside the insert.
ELECTRONIC EQUIPMENT
emergency button
rpm smoke
radio module
Antenna
lithium + cr2032
smoke expulsion motor
cochlea
left-hand
ventilation
room
temperature
probe
fl ow sensor
(optional)
thermo coupling
auxiliary
ventilation
AUX/RS485 PORT
(connected via optional serial port cable code 640560)
This is a clean, potential free contact, useful for connecting a
telephone combiner or other control devices via an optional
cable.
BACKUP BATTERY
A backup battery is found on the control board (3-Volt CR
2032 battery).
Its malfunction is indicated with the following messages: (not
considered a defect but due to normal wear-and-tear): "Batte-
ry check".
For more detailed information, please contact the DEALER
who has performed the fi rst 1st ignition.
- 24
-
mains 230 Vac
50 Hz +/-10%