4. Technical data
4.1 Bluetooth
The use of the wireless module is subject to the regulations
and stipulations of the respective country of use and the
module may only be used in countries for which a national
certification has been granted. The user and every owner has
the obligation to adhere to these regulations and prerequisites
for use and acknowledges that the re-sale, export, import,
etc., in particular in, to or from countries without wireless
authorization, is their responsibility.
4.2 General Technical data
Feature
Penetration probe
Sensor type
Measuring range
Resolution
Accuracy (±1 digit)
Response time t99
Measuring rate
Infrared measurement
Lens
Spectral range
Laser type
Output / wavelength
Class / standard
Measuring range
Resolution
Accuracy (at 23°C, ±1 digit) ±2.5 °C / ±4.5 °F (-30.0 to -20.1 °C / -22.0 to -4.2 °F)
Measuring rate
General
Operating temperature
Transportation/
storage temperature
Power supply
Housing
Protection class
Dimensions
Weight
Standards
EC Directive
12
Module
®
Values
NTC
-50 to +250 °C / -58 to +482 °F
0.1 °C/°F/°R
±1.0 °C / ±1.8 °F (-50,0 to-30,1°C / -58.0 to -22.1 °F)
±0.5 °C / ±0.9 °F (-30,0 to +99,9°C /
-22.0 to +211.9 °F)
±1 % of the measuring range (+100.0 to +250.0 °C /
+212.0 to +482.0 °F)
10 s (measured in moving liquid)
0.5 s
10:1 + opening diameter of the sensor (12 mm / 0.47")
8 to 14 μm
2-point laser
< 1 mW / 650nm
2 / DIN EN 60825-1:2007
-30 - +250 °C / -22 - +482 °F
0.1 °C/°F/°R
±2.0 °C / ±3.6 °F (-20.0 to -0.1 °C / -4.1 to 31.9 °F)
±1.5 °C / ±2.7 °F or ±1.5 % of the measuring value
(0.0 to +250.0 °C / +32.0 to +482.0 °F)
0.5 s
-20 to +50 °C / -4 to +122 °F
-30...+50 °C / -22 to +122 °F
(without batteries up to + 70 °C / + 158 °F)
2 x AAA batteries
ABS/TPE/PC and die-cast zinc/stainless steel
IP65
281 x 48 x 21 mm / 11.06 x 1.89 x 0.83" (immersion/
penetration probe folded out)
178 x 48 x 21 mm / 7.01 x 1.89 x 0.83" (immersion/
penetration probe folded up)
207 g / 0.433lbs (incl. batteries)
EN 13485