For fault alarms E-6 and E-7, check that there is no leak or an obstructed/broken hose, that the pump is not blocked or deacti-
vated and that there is enough cooling liquid in the tank.
If the problem appears to have been rectified, press the «inductor change» button twice (10) . The cooling circuit is performing
a purge cycle. It is ready to operate.
TIME DELAY MODE
*
The "Timing" function allows you to control the heating time of the Powerduction.
The time is adjustable from 1 to 30 s.
To enter this mode:
1. Press the heating authorization button (2). Its indicator light comes on.
2.  Then press both power adjustment buttons (4) simultaneously. The display shows "SEC" then "T 00"
or "SEC" then "ON" if a time has already been set.
3. The power setting buttons (4) become time setting buttons. Change the setpoint from time to time as desired.
If the time value has not been changed beyond 3 seconds and still shows "T 00", the Powerduction returns to normal
mode.
Use in "Timer" mode:
Once the time setpoint has been selected, the product is ready for operation. The lighting LED (12) is lit.
1. Press the lance button (11). The intensity of the LED (12) decreases to indicate that the heating is active.
2.  The heating stops at the end of the time limit. As long as the lance button (11) is pressed, the LED (12) and the
heating enable button (2) flash to warn that the power is off. Adjust the time setpoint if necessary.
3. Press the lance button (11) for a new heating cycle.
Exit the "Timer" mode
The mode remains active at all times, even when the Powerduction is switched off and then on again.
1. To exit the mode, set the time setpoint on ∞ or press both power control buttons (4) simultaneously. The Powerduc-
tion returns to normal operating mode. The display shows "SEC" then "OFF".
Special feature of the power setting in this mode
As explained, in normal use mode the setting buttons allow you to change the power while in this mode they change
the time setpoint. To change the power without leaving the mode:
1. Press the heating authorization button (2). Its green light goes out.
2. The setting buttons (4) allow you to change the power. Adjust the power.
3. Press button (2) again. Its indicator light comes on again. The setting buttons (4) become the time setting again.
«ACCESSORY CHANGE» MODE
1
STOP
This mode is accessible only if the heating isn't activated (green button switched off).
1. Press the button (10), the pump stops and the LED (9) switches on.
2. Place the lance on its supports and put the cable on the ground (to prevent loss of cooling liquid).
3. If the Powerduction is equipped with a complete inductor, unscrew it with the key of 27 (sup-
plied with the product). If it is equipped with a simple inductor, unscrew it manually and then
unscrew the adapter if necessary.
The Powerduction 37LG is equipped with a fixed connection S, it cannot be unscrewed.
4. Depending on the choice of the new inductor: screw on a complete inductor using the wrench
supplied or screw on the appropriate adapter (7 N.m max) and then screw on the new inductor
manually.
5. Press the button again (10).
The pump activates. For 5 seconds, the LEDs display a wait pattern.
* Valid only for Powerduction versions of V4 program versions. Previous versions are not equipped with this function.
POWERDUCTION 37LG / 39LG / 50LG
3
4
A
B
product serigraphy
5
OK
EN
Tightening torque max = 7N
2