Result: The LED changes to on and the pump starts after a delay of 2
seconds.
NOTE
- If the detection module is not turned over, or not for long enough (step
2), the green LED goes out and the new pairing is not stored.
- The pairing procedure may be repeated as often as necessary.
3. INSTALLATION
IMPORTANT
Note concerning radio communication:
To ensure optimal radio communication,
1. Remove all possible sources of radio interference nearby. Sources
of interference can be: metal structures, hi-fi speakers, the presence
of multi-layer insulation with aluminium, metal inspection hatches...
2. Install the remote box in the same room as the shower gulley.
Follow the installation steps as indicated in the enclosed manual.
3.1 SETTING UP
• The device must be easily accessible for inspection and maintenance.
• Activating the detection sensor:
◇ Remove the sensor from the gulley.
◇ Remove the red wedge from the detection sensor then replace
the sensor in the gulley.
• In order to make the most of the latest technical developments in
acoustics included in this device, it is important to:
◇ install the pump, avoiding it touching a wall of the room,
◇ place the pump on a perfectly flat floor,
◇ fasten the outlet piping correctly, avoiding any distances between
attachments in excess of one meter.

3.2 FITTING OF THE REMOTE BOX

IMPORTANT
Install the remote box in the same room as the gulley.
DANGER
Incorrect installation of the box.
Danger of electric shock!
Ö Keep a minimum distance of 60 cm between the shower and
the remote box.
Ö The socket used to connect the box must be at least 60 cm
away from the shower.
Ö The shower screen must prevent the remote box from being
sprayed with water.
To fix the remote box to the wall, refer to the dimensions diagram on
page 2.
3.3 HYDRAULIC CONNECTION
SUCTION PIPE
1. Attach the suction pipe to the gulley using cyanoacrylate glue and
tighten with the collar supplied.
2. Check the watertightness.
IMPORTANT
Any intervention linked to a watertightness problem will not be covered
by the guarantee.
DISCHARGE PIPE
IMPORTANT
In the event of horizontal discharge after
the pump (or very weak lifting), install a
vertical lifting loop of at least 30 cm above
the pump in order to always have a load on
the non-return valve and thus make it
watertight. Indeed, if the check valve is not
waterproof, there is a risk of water
returning back to the gulley hole and thus
the pump restarting.
NOTICE
Evacuation brought underneath the pump!
Risk of siphoning.
Ö Install a diaphragm aerator (vacuum breaker) at the upper
point of the discharge (see enclosed installation manual).
3.4 ELECTRICAL CONNECTION
Connect the pump to the remote box using the quick-connector cable
supplied.
Electrically connect the remote box.

4. COMMISSIONING

List of check points for commissioning:
1. Make sure that the pump tank is accessible for easy filling. Open the
pump reservoir cap. Fill the pump with 3 L of water using the card-
board funnel provided to allow priming of the pump. Make sure that the
sealing disc and then the cap are replaced.
2. Then pour 1 L of water into the gulley to perform a lifting test.
3. Check that evacuation is completed correctly: the motor starts auto-
matically, the water from the gulley is correctly pumped.
4. Check the tightness of the connections with the shower connected
to the suction pump.
5. Repeat steps 2 to 4 over several cycles.
5. MAINTENANCE
See attached leaflet.
NOTICE
Do not turn the detectino module over for extended pe-
riods of time during maintenance, cleaning or storage!
Risk of battery discharge.
Ö Store the module in the direction it occupies in the gulley.
CLEANING THE FILTER
The removable gulley sensor filter should be cleaned daily.
1. Lift the cover.
2. Lift up the filter and remove any waste accumulated on it.
3. Throw the collected waste in the bin.
NOTICE
Do not throw waste in the gulley!
Risk of clogging.
Ö Throw the waste in a bin.
4. Wash the filter with water and washing-up liquid in the sink, then
replace it.
CLEANING THE GULLEY
The gulley should be cleaned every month.
1. Remove the cover and filter.
2. Clean the gulley with soap and water.
CHECKING/CLEANING THE DETECTION MODULE
The detection module should be checked and cleaned monthly, to be
adapted according to use.
1. Remove the detection module by pulling upwards.
2. Turn the detection module over briefly (5 to 10 seconds) and check
that the pump starts up (the green LED on the remote box will light
up).
3. Remove any dirt and put it in the bin (do not throw it down the gulley).
4. Clean with water and washing-up liquid in the sink.
5. Replace by clipping the detecteur module into the gulley.
CHECKING/CLEANING THE DUCKBILL VALVE
1. Remove the detection module.
2. Remove the duckbill valve.
3. Clean with water mixed with washing-up
liquid, especially the areas above and below
the float. Rinse.
4. Put back in place, holder with the suction
hole positioned downwards.
IMPORTANT
If disassembling the float, make sure you put it back in position with the
magnet pointing upwards!
DESCALING
To descale and clean the pump and the discharge pipe, regularly use
SFA's descaler, designed to remove limescale while respecting the in-
ternal organs of your appliance.