Connection

1
3
8
* 
necessary if water pressure
> 0.5 MPa (5 bar)

Heating time of the water depending on the heating power

power
200 W
400 W
550 W
Note
The values given in the table are intended as a gui-
deline. The heating times depend on many factors
(power, ambient air temperature, water withdrawal)
and may differ from reality. The greater the connec-
2
5
6*
4
7
PVB-10
18 °C / h
36 °C / h
50 °C / h
1  
hot water tank
2
water inlet
3
water outlet
4
shut-off valve*
5
combined check and
pressure relief valve
PVB-30
6 °C / h
12 °C / h
16 °C / h
ted photovoltaic power, the more the water can be
heated on days with low solar radiation. The water
is heated with a maximum power of 550 W, even if
more photovoltaic power is available.
08
6
pressure reducing
valve*
7
cold water
8
hot water
*not included
PVB-80
2 °C / h
4.5 °C / h
6 °C / h