Before starting the machine check the correspondence between voltage
and frequency according to the data mentioned on the identification plate.
Voltage differences from + 6 % and – 10 % are allowed.
The FloorMix 2300 is made in protection class I.
Only use extension cables with a sufficient cross-section. A cross-section
(min. 2.5 mm²) which is too small could lead to an excessive power loss
and to an overheating of motor and cable.
Preselection of the speed:
The speed can be set in four stages.
This is done with the help of two gear stages and two electrically-switchable
motor stages.
Electrical Connection
Use
Stage 1 = 70 rpm
Gear stage 1 / Motor stage 1
Stage 2 = 130 rpm
Gear stage 1 / Motor stage 2
Stage 3 = 160 rpm
Gear stage 2 / Motor stage 1
Stage 4 = 280 rpm
Gear stage 2 / Motor stage 2
Only change the gear stage when the
machine has come to a complete standstill!
20