Download Inhoudsopgave Inhoud Print deze pagina

Scope Of Delivery - SimonsVoss Digital SmartHandle AX PAS24 Korte Handleiding

Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 36
Digital SmartHandle AX PAS24
Loss of the precise guidance of the handle
It may be difficult to install on mortise locks with a retaining nut.
Do not mechanically alter the locking nut. The handle would then lose
its precise guidance.
Difficult installation due to inaccurate holes
The fitting cannot be installed if the fastening holes and the spindle do not
match.
Make sure that the fastening holes and the spindle are in parallel ver-
tical lines.
NOTE
Effect on the mortise lock
The SmartHandle AX acts exclusively on the latch of the mortise lock.
Locking and insurances
Insurance companies place increased demands on a closure.
1.
If you want to lock the door under insurance law, use a self-locking
panic lock or a locking cylinder in addition to the SmartHandle AX.
2.
Pay attention to the approvals according to EN 179.
SmartHandle AX with self-locking panic lock
The SmartHandle AX only offers full functionality with a self-locking panic
lock.
1.
Combine the SmartHandle AX with a self-locking panic lock.
2.
Pay attention to the declarations of conformity of the lock manufactur-
ers according to EN 179.
Conditions for authorisation security
Operation with Mifare Classic and/or PinCode keypad excludes authorisation
security class D according to DIN EN 16867:2020.
Sealing escutcheon holes
Any escutcheon holes that exist may be used to manipulate the lock.
1.
Seal any escutcheon holes with a blind cylinder, for example.
2.
In the case of FH versions, you must be install a brass dummy cylinder or
locking cylinder.

4. Scope of delivery

SmartHandle AX (suspended installation for PAS24)
Special tool
Quick guide
Depending on version:
Adapter set, 7 mm spindle
Adapter sleeve, 8.5 mm spindle
Adapter sleeve, 10 mm spindle
Blank cylinder
5. Structure
1
6. Prepare door (drilling template)
Pin or scriber at hand.
ü
ü
Drill at hand.
ü
Suitable drill bit at hand (Ø 8.5 mm).
ü
PH2 screwdriver at hand.
1.
Remove the mortise lock (PH2).
2
2.
Measure the vertical distance between the centres of the fixing holes.
3
3.
Fit the mortise lock (PH2).
4
EN
4.
Insert the spindle into the mortise lock.
5
5.
Place the drilling template on the spindle.
6
6.
Align the drill template vertically using the printed scale.
7.
Use the distance you measured previously to determine where the
points need to be drilled.
8.
Mark the points to be drilled on the door.
7
9.
Remove the drilling template.
8
10. Remove the spindle.
9
11.
Remove the mortise lock (PH2).
10
12.
Drill the required holes.
11
13.
Fit the mortise lock (PH2).
12
7. Programming the fitting
Programme the fitting before installation. You can use different
programming devices, depending on the product family.
13
14
15
8. Installing the fitting
Door pre-drilled.
ü
PH2 screwdriver at hand.
ü
TX15 screwdriver at hand.
ü
ü
Vernier calliper at hand.
ü
Pincers at hand.
1.
Measure the door thickness.
16
Size
Door thickness (mm)
S
38 – 50
S
49 – 60
M
59 – 70
M
69 – 80
L
79 – 90
L
89 – 100
2.
Identify the L1 screws you need.
17
18
19
20
21
22
4. Scope of delivery
Screws (M4)
33
43
53
63
73
83
29 / 52

Advertenties

Inhoudsopgave
loading

Inhoudsopgave