Download Inhoudsopgave Inhoud Print deze pagina

Re-Setting The End Limits (For End Limits Set In Manual Mode); Tips And Recommendations For Installation - SOMFY Oximo 40 io Handleiding

Verberg thumbnails Zie ook voor Oximo 40 io:
Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 73

2.3.5. Re-setting the end limits (for end limits set in manual mode)

Readjusting the upper end limit
1) Press the Up button to bring the motorised product to the
end limit to be readjusted.
2) Press the Up and Down buttons at the same time until
the motorised product moves up and down.
3) Press the Up or Down button to move the motorised
product to the new desired position.
the motorised product moves up and down.
Readjusting the lower end limit
1) Press the Down button to bring the motorised product to
the end limit to be readjusted.
2) Press the Up and Down buttons at the same time until
the motorised product moves up and down.
3) Press the Up or Down button to move the motorised
product to the new desired position.
the motorised product moves up and down.
2.3.6. Modifying the direction of rotation
Position the motorised product at the mid-height position.
1)
Press the Up and Down buttons at the same time until the
2)
motorised product moves up and down.
Press the my button until the motorised product moves up
3)
and down.

2.4. TIPS AND RECOMMENDATIONS FOR INSTALLATION

2.4.1.
Questions about the
Observations
The motorised
product does not
operate.
Copyright © 2016 Somfy SAS. All rights reserved.
my button until
my button until
Oximo ?
Possible causes
The wiring is incorrect.
The motorisation is in thermal
protection.
The control point battery is weak.
The control point is not
compatible.
The control point used has not been
programmed into the motor.
1
3
1
3
1
4
Check the wiring and modify it if necessary.
Wait until the motor cools down.
Check whether the battery is weak and
replace it if necessary.
Check for compatibility and replace the
control point if necessary.
Use a programmed control point or program
this control point.
Images not contractually binding
EN
2
4
2
4
2
Solutions
7

Advertenties

Inhoudsopgave
loading

Inhoudsopgave