Download Inhoudsopgave Inhoud Print deze pagina

CAME ZD2 Handleiding pagina 11

Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 33
Adjustment Trimmer
C
- «A.C.T.»
Sets the waiting time while open. Once this time has elapsed, closing automatically takes place.
The waiting time may be set from 1 to 150 seconds.
- «PAR.OP.»
Sets the gate's partial opening. By pushing the partial opening button connected at 2-3P, the
gate opens depending on the length of the gate.
- «SLOW S.» Sets the amperometric sensitivity that controls the force generated by the motor during slow
down; if the force exceed the set level, the system intervenes by inverting the direction of
motion.
- «RUN S.»
Sets the amperometric sensitivity that controls the force generated by the motor during
movement; if the force exceeds the set level, the system intervenes by inverting the direction of
motion.
- «SLOW V.» Sets the gate's fi nal opening/closing phase slow-down speeds.
- «RUN V.»
Sets the gate's opening/closing motion speed.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.

Advertenties

Inhoudsopgave
loading

Inhoudsopgave