Download Inhoudsopgave Inhoud Print deze pagina

Installation; Switching Off The Product; Hydraulics Installation; Hydraulic Connection - Vaillant VPS R 100/1 M Installatie- En Onderhoudshandleiding

Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 46

5 Installation

4.8

Switching off the product

Applicability: VPS R 100/1 M
OR VPS R 200/1 B
1.
When selecting the installation site, note the weight of
the filled cylinder and the bearing load of the floor.
Weight when filled with water
Applicability: VPS R 100/1 M
Applicability: VPS R 200/1 B
2.
Remove the fixing screws from the cylinder below the
pallet.
3.
Set up the three enclosed feet below the cylinder.
72
135 kg
246 kg
1
2
4
3
4.
Use the adjustable feet and a spirit level to align the
product.
5
Installation
5.1

Hydraulics installation

5.1.1

Hydraulic connection

Caution.
Risk of material damage caused by
residues in the pipelines.
Welding remnants, sealing residues, dirt or
other residues in the pipelines may damage
the product.
Flush the heating installation thoroughly
before installing the product.
Caution.
Risk of damage caused by heat transfer
when soldering.
The heat that is transferred during solder-
ing may lead to damage to the expanded
polypropylene around the product and to the
seals on the connectors.
Protect the product's insulating casing.
Do not solder the connectors if these have
been screwed onto the product.
Installation and maintenance instructions 0020244064_01