SinePower
12
Troubleshooting
!
WARNING!
Do not open the device. You risk sustaining an electric shock by doing
this.
I
NOTE
If you have detailed questions on the specifications of the inverter
please contact the manufacturer (addresses on the back of the instruc-
tion manual).
The "Load Status" LED (fig. 6 3, page 4 and fig. 7 3,page 5) lights up red to
indicate the fault:
LED display
Quick flash
Slow flash
Occasional flash
Constantly lit
EN
All manuals and user guides at all-guides.com
Cause
Input voltage is too high
Input voltage too low
Overheating
Short circuit or reversed
polarity
Excessive load
Troubleshooting
Remedy
Check the input voltage and reduce
it.
The battery needs recharging.
Check the cables and connections.
Switch off the inverter and the con-
sumer.
Wait 5 to 10 minutes and switch the
inverter on again without any elec-
tric consumers.
Reduce the load and make sure the
inverter has better ventilation. Then
switch the consumer back on.
Switch off the inverter and remove
the consumer.
Then switch the inverter back on
without the consumer. If no
excessive load is now shown, then
there is a short circuit in the con-
sumer or the total load was higher
than the power specified on the
data sheet. MSI1812T and
MSI1824T: The fuse in the device
must be pressed in again by hand
after it is triggered.
Check the cables and connections.
29