Download Print deze pagina

Dometic SINEPOWER MSI912 Montagehandleiding En Gebruiksaanwijzing pagina 17

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 169
SinePower
8
Fitting the inverter
8.1
Tools required
For the electrical connection you will need the following tools:
• Crimping tool
• 3multi-coloured, flexible connection cables. Determine the necessary thickness
from the table in chapter "Connecting the inverter" on page 18.
• Cable lugs and conductor sleeves
For fastening you will require the following tools:
• Machine bolts (M4) with washers and self-locking nuts or
• self-tapping screws or wood screws.
8.2
Mounting instructions
When selecting the installation location, observe the following instructions:
• The inverter can be mounted horizontally or vertically.
• The inverter must be installed in a place that is protected from moisture.
• The inverter may not be installed in the presence of flammable materials.
• The inverter may not be installed in a dusty environment.
• The place of installation must be well ventilated. A ventilation system must be
available for installations in small, enclosed spaces. The minimum clearance
around the inverter must be at least 25 cm (fig. 3, page 3).
• The air intake on the underside or the air outlet on the back of the inverter must
remain clear.
• For ambient temperatures higher than 40 °C (such as in engine or heating com-
partments, or direct sunlight), the heat from the inverter under load can lead to
automatic shutdown.
• The device must be installed on a level and sufficiently sturdy surface.
A
NOTICE!
Before drilling any holes, make sure that no electrical cables or other
parts of the vehicle can be damaged by drilling, sawing and filing.
EN
All manuals and user guides at all-guides.com
Fitting the inverter
17

Advertenties

loading