Installation
1. After completition of the wall surface and instal-
lation of the take off fi ttings, the grey fl ushing
unit must be removed and the box has to be
shortened to the front edge of the tiles.
2. Seal with silicone. When used in hollow wall
installation seal the edge to the gipsom board.
3. Put on the installation unit (cold water mark up
right hand side), sleeve, cover plate and adapter
shaft. 4.Mount setting knob in position 38° and
tighten screw.
Adjustment
Correction is necessary if the temperature measured
at the take off point differs from the temperature
set on the scale. To adjust temperature proceed as
follows: Turn the setting knob until water at a tem-
perature of 38° C comes out of the outlet. Loosen
screw of setting knob. Remove setting knob and turn
to the 38° C position. Attach setting knob again and
tighten its screw.
1
1
- 2
m m
3
8
English
Temperature limitation
The temperature range is limited by the safety check
to 38° C. If a higher temperature is required, it is
possible to override the 38° C check by depressing
the red safety button.
Maintenance of the thermoelement
The shut-off valves are automatically closed by
removing the none return valves.
Put setting knob to 38° C and hold in position.
Undo screw and pull off setting knob.
Remove cover plate (velcro straps) holder for cover
plate and seal.
Close the shut-off valves clockwise with an allen
wrench (8 mm).
Remove the thermoelement.
Clean fi lters and lubricate the seals.
Important!
Do not dismantle the thermoelement only replace
it complete.
Reassemble in reverse order.
Adjust unit.
To garantee a smooth running of the thermoelent, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
2
4