The device is suitable for vacuuming flam-
mable dusts, installation outside zone 22.
WARNING: This device must not be placed
in any zone 22. If a zone 22 is present, an
EX-device must be used.
The maximum vacuum value in relation to
the hose cross-section is specified on the
label. The actual value can be read on the
pressure gauge. For the values applicable
to this device, see chapter Reading the
minimum volumetric flow. If this value is not
reached, the main filter must be cleaned
(see chapter Cleaning the main filter) or re-
placed (see chapter Replacing the main fil-
ter). The various different hose cross-
sections allow adaptation to the various dif-
ferent connection cross-sections of the ac-
cessories.
IVR 60
Dust bag
(Order no. 9.989-606.0)
Safety filter bag
(Order no. 6.904-420.0)
Main filter
(Order no. 9.981-681.0)
H14 filter
(Order no. 9.980-249.0)
IVR 100
Dust bag
(Order no. 9.989-607.0)
24
IVR 100
Safety filter bag
(Order no. 6.904-420.0)
Main filter
(Order no. 9.981-681.0)
H14 filter
(Order no. 9.980-249.0)
Top-heavy device
Further instructions must be ob-
served when transporting or mov-
ing the device.
Initial startup
WARNING
Potential equalisation line not connect-
ed correctly
Electric shock
Every time before use, check whether the
equipotential bonding conductor (earthing
conductors) are connected.
WARNING
Danger from dust that is harmful to your
health
Respiratory sicknesses through inhalation
of dust.
Do not vacuum without correctly installed
filter elements, otherwise a danger to
health from increased fine dust emission is
present.
ATTENTION
Missing filter element
Damage to the suction motor
Do not vacuum without a filter element.
1. Bring the device into the working posi-
tion.
2. Secure the device with the parking
brakes.
3. Ensure that the suction head is fitted
correctly.
4. Insert the suction hose (not included in
the scope of delivery) into the suction
connection.
5. Check the filling level in the dirt recepta-
cle (see chapter Check the dirt recepta-
cle filling level).
English