shoes when operating the device. ● Only
move the device at walking speed, and to
move down a decline, have two workers
steady the device as necessary. ● Be care-
ful to ensure that there is no dust spillage
when replacing accessories. ● Surface
temperatures can rise to 135° C during nor-
mal operation. ● Avoid kinking the suction
hose unit. ● Carry out a regular visual in-
spection of the hoses.
Electrical connection
The device may only be connected to an
electrical connection which has been set up
by a qualified electrician as per IEC 60364.
For connected loads see Technical data
and type plate.
DANGER
Danger of electric shock
Danger of death
Avoid damaging the power cables by driv-
ing over them or otherwise crushing them,
or by jerking them.
Protect the cables from heat, oil and sharp
edges.
Check the mains connection of the device
for damage every time before operation.
Do not operate the device using a damaged
cable. Have any damaged cables replaced
by a qualified electrician.
Behaviour in the event of an
emergency
DANGER
Risk of injury and damage in the event
of a short-circuit or other electrical
faults
Danger of electric shock, danger of burns
Switch off the device and unplug the mains
plug.
Behaviour in case of filter breakage /
leakage:
1. Switch off the unit immediately.
The unit may not be operated without
the fresh water filter.
2. Replace the filter.
22
Intended use
The device is intended for:
● Wet and dry cleaning of floor and wall
surfaces
● Extraction of dry, flammable, deposited
dusts hazardous to health; dust class H
according to EN 60335-2-69
● Vacuuming of non-explosive substances
● Vacuuming of flammable dusts of all
dust explosion classes (excluding dusts
with a minimum ignition energy
ME < 1 mJ)
● Vacuuming of dusts and coarse dirt
● Vacuuming of flammable dusts from a
zone 22 if the device is installed outside
of potentially explosive areas
● Vacuuming moist and liquid substances
● Commercial use, e.g.in hotels, schools,
hospitals, factories, shops, offices, and
rental companies
● Industrial usee.g in storage and produc-
tion areas
A corresponding Ex device must be used if
there is a classified Ex zone at the device
installation location.
The device's correct function is only guar-
anteed when using suction hose nominal
widths of DN40 and DN50.
Any other use constitutes improper use.
The device is not suitable for:
● Vacuuming of ignition sources and dusts
with a glow temperature ≤ 190 °C
● vacuuming of explosive or equivalent
substances as defined in §1 SprengG,
explosive steam/air mixtures, as well as
Al and Mg dusts
● vacuuming of flammable liquids (flam-
mable, easily flammable, highly flamma-
ble according to Dangerous Substances
Directive 67/548/EEC) (flash point be-
low 55 °C) and mixtures of flammable
dusts and liquids
● vacuuming of magnesium dust or pow-
der
● vacuuming of mixtures of flammable liq-
uids and flammable dust
● Vacuuming of smouldering or hot parti-
cles where this could otherwise result in
a fire or an explosion
English