SinePower
The inverter has the following connections, displays and control elements:
Pos. in
fig. 1,
Element
page 3
1
Switches
0: device is switched off
I: device is switched on
2
Green Status LED: lights up when inverter is in operation
3
Red Status LED: indicates malfunction
4
USB port
5
Cover for 230 V w-safety socket
6
Holders
Pos. in
fig. 2,
Element
page 3
1
Connection cable for direct current
2
Fan
6
Fastening the inverter
You can fasten the inverter using the four holders supplied.
When selecting the installation location, observe the following instructions:
The inverter can be mounted horizontally or vertically.
The inverter must be installed in a place that is protected from moisture.
The inverter may not be installed in the presence of flammable materials.
The inverter may not be installed in a dusty environment.
The place of installation must be well-ventilated. A ventilation system
must be present for installations in small, closed spaces. The minimum
clearance around the inverter must be at least 25 cm.
The air intake on the underside or the air outlet on the back side of the
inverter must remain clear.
EN
Fastening the inverter
23