GENERAL
INFORMATION
AUTOMATIC MODE
Comfort mode active. At set comfort temperature.
Reduced mode active. At set reduced temperature.
The
, in section 8 of the LCD display, blinks.
Frost protection mode is active.
The
, in section 8 of the LCD display, blinks.
The radiator is switched off. The
the LCD display, blinks.
The
icon is active when wireless programmer and
radiator thermostat exchange information (e.g. order
to change the operating mode).

OTHER FUNCTIONS

TIMER FUNCTION
The timer function allows you to override the
programmed settings (temperature and operating mode)
for a chosen period of time, starting from the moment
that the timer function is activated.
Move the frame cursor to the timer icon.
Confirm your choice with the "OK" key.
Adjust the period using the "+" and "-" keys between
1 hour and 44 days. Confirm with the "OK" key.
Set the desired temperature using the "+" and "-"
keys and confirm with the "OK" key.
The timer icon will start to blink and the number
of hours/days left is displayed until the end of the
set period.
If you want to stop the timer before the end of the set
period, press the "-" key until the "no" appears on the display.
POWER SETTING
The power setting can be used to limit the output of the
heating element in the front panel and as a consequence
the surface temperature of the front panel.
Move the frame cursor to the power icon.
Confirm your choice with the "OK" key.
| 24
LVI0014_Manual Ramo_Parada_ZW_v5.indd 24
All manuals and user guides at all-guides.com
Use the "+" and "-" keys to change the output of the
front panel from 100% (Index 3 in section 2 of the LCD -
Factory setting) to 70 (Index 2 in section 2 of the LCD) or
55% (Index 1 in section 2 of the LCD) (corresponding to
a maximum surface temperature of 90, 75 or 60°C) and
confirm with the "OK" key.
The thermostat will return to the "AUTO" mode.
The display will then show in the right upper corner
(section 2 of the LCD) the index corresponding to the
maximum surface temperature of the front panel.
When considering the permanent use of the radiator at
60°C or 75°C maximum, the following correction factor
should be applied for the output.
, in section 8 of
INDEX IN
SECTION 2
1
2
3
E.g. A 1000 Watt single panel programmed for a
maximum surface temperature of 75°C will deliver
maximum 700 Watts. A 1000 Watt double panel
programmed for a maximum surface temperature of
60°C will deliver maximum 800 Watts. These values
should be considered when selecting the number and
type of panels to cover the calculated heat losses.
Use the Key Lock function to prevent any changes to
your settings (in a child's room, public area ... etc)
To activate the Key Lock function, first press and maintain
the "OK" key and then simultaneously on the left ""
navigation key.
The key icon will be displayed on the screen.
Repeat the same procedure to unlock the keyboard.
This function is available in all operating modes.
WINDOW OPEN FUNCTION
The radiator is equipped with a "window open" function.
This function will switch the radiator from any active
mode to "Frost Protection" mode when an open window
is detected (room temperature drops by more than 5°C
SURFACE
SINGLE
TEMPERATURE
PANEL
60°C max
~ 0.55
75°C max
~ 0.70
90°C max
1
KEy LOCK FUNCTION
DOUBLE
PANEL
~ 0.80
~ 0.90
1