Technical data
Pressure cleaner .........PHD 150 B2
Mains connection .............. 230V~, 50 Hz
Power consumption ....................2100 W
Mains cable length ............................5 m
Weight (without accessories) ........10.8 kg
Safety class ......................................
Degree of protection ......................... IPX5
Rated/operating pressure (p) ........11 MPa
Max. permissible pressure (p max) ...15 MPa
Max. inflow pressure (p in max) ...0.8 MPa
Max. inflow temperature (T in max) ...40°C
Pumping rate, water (Q)............ 5.5 l/min
Max. pumping rate, water
(Q max) .................................. 7.5 l/min
Sound pressure level
(L
) .............78.2 dB(A); K
pA
Sound power level
(L
WA
measured ... 91.7 dB(A); K
guaranteed
........................ 98.0 dB(A)
Vibration
(a
) ......0.496 m/s
n
Do not exceed the maximum permitted
network impedance of 0.277 Ohms at the
electrical connection point.
The user must ensure that the device is
operated only on a power supply network
that fulfils this requirement.
If necessary, the local power supply com-
pany can be asked for the system imped-
ance.
Technical and optical changes can be
carried out in the course of further develop-
ment without notice. All dimensions, refer-
ences and information of this instruction
manual are therefore without guarantee.
Legal claims, which are made on the basis
of the instruction manual, cannot thus be
considered as valid.
All manuals and user guides at all-guides.com
II
= 3.0 dB(A)
pA
)
= 3.0 dB(A)
wA
; K=1.5 m/s²
2
Notes on Safety
This section is concerned with the basic
safety rules when working with the pres-
sure cleaner.
Explanation of symbols
Attention!
Before beginning work, familiarise
yourself thoroughly with all the op-
erating elements, particularly with
how they function and operate. Ask
a specialist if necessary.
Attention: Remove the plug from the
socket as soon as the power lead is
damaged or cut.
Also disconnect the plug from the
socket when connecting to the
water supply or trying to eliminate
leaks.
The pressure cleaner is not suitable
for direct connection to the drinking
water supply system.
Safety class II
Electric appliances should not be dis-
posed of in the domestic garbage.
CAUTION. pressure cleaners
can be dangerous if they are
not operated correctly! The
jet must never be directed
at people, animals, electric
equipment connected to the
power supply or against the
actual pressure cleaner.
Operate the equipment
only in an upright and
never in a reclined po-
sition.
GB
31