5.5.3 Exemplary settings
Example 1 is the factory setting
ds-1
ds-2 Panel option
ds-3 Ch. voltage
ds-4 Ch. voltage
ds-5 Frequency
ds-6 Search mode
ds-7 AC-in Limit
ds-8 Store setting
Example 1: (factory setting)
1
No panel or remote
switch connected
2
No panel or remote
switch connected
3, 4
GEL 14.4 V
5
Frequency: 50 Hz
6
Search mode off
7
AC-in Limit 16 Amp
8 store setting: off→ on→ off
Store the settings (ds-3 to ds-7) by changing switch ds-8 from "off" to "on", and then
back to "off".
The LED's "charger" and "alarm" will flash to indicate acceptance of the settings.
6. Maintenance
The Compact does not require specific maintenance. It will suffice to check all
connections once a year. Avoid moisture and oil/soot/vapours, and keep the device
clean.
22
off
ds-1
on
ds-2
off
ds-3
off
ds-4
off
ds-5
off
ds-6
off
ds-7
→ ←
ds-8
Example 2
1
2
3,4
5
6
7
8 store setting: off→ on→ off
off
on
off
on
off
off
on
→ ←
Example 3
No panel or remote
1
switch connected
No panel or remote
2
switch connected
AGM 14,7 V
3, 4
Frequency: 50 Hz
5
Search mode off
6
AC-in Limit
7
30 Amp
8 store setting: off→ on→ off
ds-1
on
ds-2
off
ds-3
on
ds-4
on
ds-5
on
ds-6
on
ds-7
off
→ ←
ds-8
Panel or remote
switch connected
Panel or remote
switch connected
Tubular plate 15 V
Frequency: 60 Hz
Search mode on
AC-in Limit
16 Amp