Download Inhoudsopgave Inhoud Print deze pagina

Electrodes Adjustment; Pump Pressure - Riello RG0.2R Installatie-, Gebruiks- En Onderhoudsvoorschriften

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

B
Fig. 12
Remove nozzle-holder assembly (1) after loos-
ing screws (2) and nut (3), remove the small ca-
bles (4) from the control box, the photoresist-
ance (6) and the socket (10).
Withdraw the small cables from the electrodes,
remove the diffuser disc-holder assembly (11)
from the nozzle-holder assembly (1) after loos-
ing screw (3, fig. 13).
Screw the nozzle (12) correctly and tighten
it as shown in figure.
ATTENTION
During the reassembly of the nozzle-holder
assembly screw the nut (3) as shown in the figure
below.
TIGHTEN WITHOUT MOVING
BACKWARDS TO THE END

4.3 ELECTRODES ADJUSTMENT

WARNING
Lean the diffuser disc-holder as-
sembly (1) on the nozzle-holder (2)
and lock it by screw (3).
For prospective adjustments of the
electrodes assembly (4), loosen
screw (5).
To have access to the electrodes
carry out operation as described in
ch a p t e r " 4 . 2 R E C O M M E N D E D
NOZZLES" (page 6).

4.4 PUMP PRESSURE

The pump leaves the factory set at 12 bar.
To change it act on pump pressure adjust screw (5, fig. 7, page 4).
1955
All manuals and user guides at all-guides.com
D5684
3
(see fig. 13)
Fig. 13
B
Fig. 12
0
4.5
– 0.5 mm
4
5
3
2
D5732
7
GB
S7223
WARNING
MEASURES
MUST BE RESPECTED
±
2.5
0.2 mm
0
1
3
+ 0.5 mm

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Rg0.3r37358103736010

Inhoudsopgave