Download Inhoudsopgave Inhoud Print deze pagina

Installation; Safety; General Safety Instructions; Instructions, Standards And Regulations - Stiebel Eltron SHU 5 SLi comfort Handleiding Voor Bediening En Installatie

Gesloten drukvaste, kleine
Verberg thumbnails Zie ook voor SHU 5 SLi comfort:
Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 29

INSTALLATION

Safety

INSTALLATION
6.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
6.1

General safety instructions

We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
6.2

Instructions, standards and regulations

Note
Observe all applicable national and regional regulations
and instructions.
6.3

Information on the safety assembly

Material losses
!
Never exceed the operating pressure.
Material losses
!
Route the drain pipe of the safety assembly with a slope
and leave it open to the atmosphere.
Material losses
!
The safety equipment requires regular maintenance and
activation (see installation instructions of the safety as-
sembly).
If using a plastic stench trap (e.g. DN 40 for the sink), there is no
need for the SVMT immersion pipe. Connect the overflow funnel,
e.g. using the washing machine connection.
7.

Appliance description

The sealed unvented (pressurised) appliance is only suitable for
undersink installation. The appliance is intended for heating cold
water and for supplying one or several draw-off points.
The appliance may only be installed with pressure taps in con-
junction with the SVMT safety assembly (see chapter "Installation /
Appliance description / Required accessories").
7.1

Standard delivery

Delivered with the appliance are the following:
- Wall mounting bracket
SHU 10 SLi
- Installation template
14
| SHU 5 | SHU 10
7.2

Required accessories

The following accessories are available for sealed unvented op-
eration:
- SVMT safety assembly for undersink installation
- Water distribution tees
8.

Preparation

Water installation
A safety assembly is required.
Taps/valves
Only install pressure taps in conjunction with the SVMT safety
assembly.
8.1

Installation site

Material losses
!
Install the appliance in a room free from the risk of frost.
Material losses
!
Mount the appliance on the wall. The wall must have a
sufficient load-bearing capacity.
Material losses
!
The appliance is only suitable for undersink installation.
The water connections of the appliance point upwards.
Note
Ensure that the appliance is freely accessible for main-
tenance work.
Always install the appliance vertically and near the draw-off point.
100-200
°C
82
35
65 Eco
55
www.stiebel-eltron.com

Advertenties

Inhoudsopgave

Probleemoplossen

loading

Deze handleiding is ook geschikt voor:

Shu 5 sl gbShu 10 sli comfort

Inhoudsopgave