UK
Select the heating/cooling/auto mode setting A in the menu and press the settings button B. Press
C or D to choose between Heating, Cooling or Auto mode. Press the settings button B to exit. The
default mode is Heating.
Working mode
Heating/Auto mode
Cooling
How the Auto Mode works
NO
Condition
1
When the heat pump
starts
When the heat pump is
running
2
When the heat pump
starts
When the heat pump is
running
Parameter
Tset
Tset-1
Tset+1
140
Temperature range
6-41°C
6-35°C
T1=Water inlet temperature /Tset= set temperature=28°C
Current working sta-
tus
Startup
Heating mode
Standby
Cooling mode
Standby
Startup
Heating mode
Standby
Cooling mode
Standby
Explanation
T water temperature setting.
For example : Tset = 28°C water temperature setting
Minus 1°C than Tset temperature.
For example: 28-1=27°C
Plus 1°C than Tset temperature.
For example: 28+1=29°C
Water inlet Temperature
T1≤27°C
T1≥29°C last for 3 min-
utes
T1≥30°C
T1=28°C, last for 3 min-
utes
T1≤27°C, last for 3 min-
utes
27°C<T1≤29°C
T1≥29°C, last for 3 min-
utes
T1≥30°C
T1=28°C, last for 3 min-
utes
T1≤27°C, last for 3 min-
utes
MV-1401-1402-1403-1404-10-2021 . © All rights reserved Swim & Fun A/S
Working mode
Heating mode
Standby
It switches to cooling
mode
Standby
It switches to heating
mode
Heating mode
Standby
It switches to cooling
mode
Standby
It switches to heating
mode