Display brightness adjustment

By pressing and holding the pushbutton
(10) and
-
pressing at the same time the push-
button (9), the display brightness
increases,
-
pressing at the same time the push-
button
(8), the display bright-
ness decreases.
When adjusting the display brightness,
the display shows the following indica-
tions:
1.8 – minimum brightness
2.8 – medium brightness
3.8 – maximum brightness (manufactur-
er's setting).
Alarms
Normal use of the refrigerator-freezer may
cause different situations leading to inter-
ruption of various functions and unstable
operation of the entire equipment as a
consequence. These interruptions are
shown on the display as the alarm code
(an E followed by a number) and signalled
by the acoustic alarm.
In case there will be several faults the
alarm codes shall be displayed in turn.

Alarm codes

E1 – temperature sensor fault in the re-
frigerator's chamber
E2 – temperature sensor fault in the
freezer's chamber
E4 – door is open
E5 – too high temperature inside the
freezer's chamber
All manuals and user guides at all-guides.com
E1, E2
One of the temperature sensors has been
damaged. Call technical service. The
built-in emergency program maintains the
admissible temperature until the fault will
be eliminated by the authorized technical
service.
E4
The door of the refrigerator's chamber or
freezer's chamber has been opened for
more than 3 minutes (refrigerator) and 2
minutes (freezer). The alarm code disap-
pears when the door is closed.
E5
The temperature inside the freezer's
chamber has been exceeding.

Interrupting an alarm

The acoustic alarm can always be inter-
rupted by opening the door and/or press-
ing any push-button.
The alarm code E4 - E5 can be cancelled
by pressing for 7-8 seconds at the same
time the push-buttons.
The exception: in case of the alarm E1 it
is possible to cancel the alarm only after
replacing damaged sensors.
In such cases please contact Gram Serv-
ice Center.