CORRECT USE
The RPD10ER - RPD40ER tubular drives are designed for the exclusive purpose of operating shutters and sun-blind systems.
They serve to open and close these systems and replace the person that is usually operating the installation. Therefore, tubular
drives may only be installed in faultless shutter- or sun-blind systems. Rough-running systems have to be repaired. Replace
defective parts. This guarantees safe operation and avoids damage during opening or closing. Any other form of usage is deemed
to be incorrect. Neither the manufacturer nor the supplier assumes any liability for personal injury, damage to property or consequential
injury or damage occurring as a result of the use of the control units and / or drives for purposes other than those mentioned above or
due to changes made to the equipment affecting the safety of the given system. The details stipulated in the Operating Instructions in
respect of the operation and repair of the system require strict observance.
Neither the manufacturer nor the supplier assumes any liability for personal injury, damage to property or consequential injury
or damage occurring as a result of non-compliant actions. In compliance with standard EN 60 335-2-97 he cable connecting the
drives to the mains cable must be laid internally. According to DIN18073 shuter box lid must always be easily accessible and removable.
PERFORMANCE FEATURES
Model
Diameter
Torque
mm
Nm
RPD10ER
35
10
RPD15ER
45
15
RPD25ER
45
25
RPD40ER
45
40
MAX. AREA (AREA = LENGTH X WIDTH)
RPD10ER
RPD15ER
PVC
5m
7,5m
2
ALU
4m
6m
2
WOOD
2m
3m
2
AWNING
CARTON CONTENTS
1. Motor
2. Connecting cable 220V (1.8m)
3. Remote control
4. Drive adapter safety catch
5. Square pin (RPD10ER)
6. Square pin (RPD15ER - RPD40ER)
7. Shaft adapter (RPD10ER 40mm, RPD15ER-
40ER 60mm)
8. Awning adapter (RPD40ER 78mm)
9. Wall bracket
10. Cotter pin
11. Screws (RPD15ER - RPD40ER)
12. Manual
INSTALLATION
Fully unroll the shutter (a). Remove the shutter material
from the tube (b). Remove the manual control (c).
b
Operating
Frequen -
Speed
Voltage
rpm
V
17
230
17
230
15
230
12
230
RPD25ER
RPD40ER
11m
16m
2
2
2
9m
12m
2
2
2
5m
7m
2
2
2
20m²
c
a
Fig. 2
Current
Motor
cy
input
Rating
Hz
A
W
50
0,71
165
50
0,78
178
50
1,03
235
50
1,20
275
REMOTE CONTROL MODEL 041ARTX1
Specifications
Frequency
Transmitting power
Battery
1
4
5
7
Remove the tube.
Fig. 3
21
Insu-
Operating
Noise
lation
time *
level
class
min
dB
4
< 35
I.CI.F
4
< 45
I.CI.F
4
< 45
I.CI.F
4
< 45
I.CI.F
433.30MHz, 433.92MHz, 434.54MHz
7
2
6
10
11
8
Pro-
tection
Weight
class
IP
kg
44
1,60
44
2,30
44
2,80
44
3,00
* 145°C / 20min. cooldown
< 10mW
CR2032 / 3V
9
12
Rohrmotor RPD10 -RPD15 - RPD25 - RPD40
Automatisches Öffnen und Schließen von Rollladen
de
Moteur tubulaire RPD10 -RPD15 - RPD25 - RPD40
Ouvre et ferme automatiquement les volets roulants
fr
Tubular Motor RPD10 -RPD15 - RPD25 - RPD40
Automatically Opens and Closes Shutters
en
Buismotor RPD10 -RPD15 - RPD25 - RPD40
Voor het automatisch openen en sluiten van rolluiken
nl
Chamberlain GmbH
Saar-Lor-Lux-Str. 19
66115 Saarbrücken
Germany
WEEE-Reg.Nr. DE66256568
www.chamberlain.eu
info@chamberlain.com
W1-709328C
2019, all rights reserved
3
Fig. 1
en