408 Signaaluitgang 45 (OUTPUT 45)
Waarde:
Control ready (CONTROL READY)
Unit ready (UNIT READY)
Ready - remote control (UNT RDY RCTL)
Enabled (ENABLED noWR)
Running (RUNNING)
Running, no warning (RUNNING noWR)
Running in range, no warning (RUNinRANGE)
Speed = reference, no warning
(RUN@REF noWR)
Alarm (ALARM)
Alarm or warning (ALARM or WARN)
Current limit (CURRENT LIMIT)
Out of frequency range (OUT FREQ RGE)
Warning of F low (LO FREQ. WARN)
Warning of F high (HI FREQ. WARN)
Out of current range (OUT CURR RGE)
Warning of I low (LO CURR. WARN)
Warning of I high (HI CURR. WARN)
0 - 100 Hz
0-20 mA (100 Hz 0-20 mA) [17]
0 - 100 Hz
4-20 mA (100 Hz 4-20 mA) [18]
# 0 - f
0-20 mA (Fmax 0-20 mA)
MAX
0 - f
4-20 mA (Fmax 4-20 mA)
MAX
REF
- REF
0-20 mA (REFmax 0-20 mA) [21]
MIN
MAX
REF
- REF
4-20 mA (REFmax 4-20 mA) [22]
MIN
MAX
FB
- FB
0-20 mA (FBmax 0-20 mA) [23]
MIN
MAX
FB
- FB
4-20 mA (FBmax 4-20 mA) [24]
MIN
MAX
0 - I
0-20 mA (CURmax 0-20 mA) [25]
MAX
0 - I
4-20 mA (CURmax 4-20 mA) [26]
MAX
0 - I
0-20 mA (CURlim 0-20 mA) [27]
LIM
0 - I
4-20 mA (CURlim 4-20 mA) [28]
LIM
0 - kW
0-20 mA (PWRlim 0-20 mA) [29]
MAX
0 - kW
4-20 mA (PWRlim 4-20 mA) [30]
MAX
Functie:
Zie functie onder parameter 407.
Beschrijving van de keuze:
Zie beschrijving van de keuze onder parameter 407.
# = fabrieksinstelling Tekst in ( ) = displaytekst. Getallen in [ ] worden gebruikt bij buscommunicatie.
68
VLT
®
3500 HVAC
409 Relaisuitgang 01 (RELAY 01)
Waarde:
[0]
Control ready (CONTROL READY)
[1]
Unit ready (UNIT READY)
[2]
Ready - remote control (UNT RDY RCTL)
[3]
Enabled (ENABLED noWR)
[4]
Running (RUNNING)
[5]
Running, no warning (RUNNING noWR)
[6]
Running in range, no warning (RUNinRANGE)
Speed = reference, no warning
[7]
(RUN@REF noWR)
[8]
# Alarm (ALARM)
[9]
Alarm or warning (ALARM or WARN)
[10]
Current limit (CURRENT LIMIT)
[11]
Out of frequency range (OUT FREQ RGE)
[12]
Warning of F low (LO FREQ. WARN)
[13]
Warning of F high (HI FREQ. WARN)
[14]
Out of current range (OUT CURR RGE)
[15]
Warning of I low (LO CURR. WARN)
[16]
Warning of I high (HI CURR. WARN)
Motor thermal overload (MOT.THERM.WARN) [17]
Ready and no motor thermal overload
[19]
(READY+MOT.OK)
[20]
Ready and remote control (RDY+MOT+REM) [19]
Ready and no over-/undervoltage
(RDY+DC V OK)
Idle running current (NO LOAD CURR)
Functie:
U kunt relaisuitgang 01 en relaisuitgang 04 gebruiken
om status en waarschuwingen aan te geven. Het
relais wordt geactiveerd wanneer aan de voorwaar-
den voor de gekozen data-waarden is voldaan.
Activering/deactivering kan worden vertraagd indien
men parameter 316 en 317 gebruikt. Wanneer
relaisuitgang 01 niet actief is, is er verbinding tussen
klem 01 en klem 03, maar niet tussen klem 01/03 en
klem 02 (wisselcontact).
Beschrijving van de keuze:
[0]-[16]: Zie uitleg onder parameter 407.
[17] Therm. overbelasting motor. De elektronische
therm. motorbeveiliging geeft oververhitting aan.
[18] Gereed en geen therm. overbelasting. De VLT is
gereed en de elektronische motorbeveiliging
geeft aan dat er geen therm. overbelasting is.
[19] Gereed, afstandsbediening: De VLT is gereed en
is in remote control-stand (Auto).
[20] Gereed en geen over-/onderspanning: De VLT is
gereed en de tussenkringspanning is OK.
[21] Nullaststroom moet worden gekozen, (par. 332)
aangezien het relais deze informatie gebruikt om
aan te geven of de V-riem gebroken is.