GB/IE/NI
1x Operation and safety notes (without fig.)
Description of parts:
1x Metal adapter for balls
2a
1x Plastic adapter for inflatable toy etc.
2b
1x Plastic adapter for air mattresses etc.
2c
1x Pump head
3
1x Lever
3a
1x Tread
4
1x Pump handle
5
1x Pump hose
6
1x Pressure gauge
7
1x Red indicator
8
2x Clamping device
9
1x Connection clip
10
4. Technical specifications
Type: XL Floor Pump
IAN: 436312_2304
Monz Item No.: 26241
Project: PO30030330
Max. permissible pressure: 8 bar (116 PSI)
Rated pressure: 6 bar (87 PSI)
Pressure gauge: up to 11 bar (160 PSI)
Displacement: 476 ml / 476 cm³
Hose length: approx. 100 cm
Production date: 10/2023
Warranty: 3 years
5. Safety information
WARNING!
1
Risk of injury and suffocation!
If children play with the product or
the packaging, they may injure
themselves or suffocate!
-
Do not let children play with the product or the
packaging.
-
Supervise children who are close to the product.
-
Keep the product and the packaging out of the
reach of children.
WARNING!
1
Risk of injury!
Not suitable for children under the
age of 8! There is a risk of injury!
- Children from the age of 8, as well as peo-
ple with impaired physical, sensory or men-
tal capabilities or with a lack of experience
8
and knowledge, must be supervised when
using the product and/or be instructed regarding
the safe use of the product and understand the
6
resulting dangers.
-
Children are not allowed to play with the product.
-
Maintenance and/or cleaning of the product is
not allowed to be performed by children.
Observe national regulations!
-
Observe the applicable national requirements
and regulations for the use and disposal of the
product.
Pay attention to ambient conditions!
-
The product is not allowed to be used in tempera-
tures above 40°C and/or below -10°C.
WARNING!
1
Risk of explosion and injury!
Risk of explosion and injury when
damaged pumps are used!
- Pumps with damaged connecting parts or
other defects or damage may no longer be used
due to the danger of explosion and injury.
-
Defective pumps must be disposed of properly.
WARNING!
1
Risk of explosion!
Risk of explosion when exceeding
the maximum value!
- You can pump up all bicycle tyres up to the
indicated maximum permitted pressure of the pump
8 bar (116 PSI). Make sure not to exceed the maxi-
mum air pressure specified by the tire manufacturer.
These can be found on the tyre wall.
-
The indicated maximum values must not be ex-
ceeded at any time!
WARNING!
1
Risk of burning!
Friction between the pump piston
and cylinder can cause them to heat
up significantly during longer
pumping. Risk of burning!
-
After pumping, only hold the pump on the pump
handle, to avoid burns.
CAUTION!
2
Risk of injury!
Risk of injury with incorrect tyre
pressure!
- Some bicycle valves do not allow pressure
indicating. For your own safety, please check the
air pressure using a calibrated pressure gauge
(e.g. at a petrol station).
6. Start-up
1. Remove all packaging materials.
2. Check whether all parts are available and un-
damaged.
If this is not the case, notify the specified service
address.
7. Purposes of the pump head and
the adapters (fig. C1)
NOTE!
Before you attach the pump head
3
, to the valve, or
put in a adapter, flip the lever
3a
upwards.
Adapter:
The adapters are in an adapter box
2
, which is at-
tached to the product,
1
see fig. A2.
1. Slide the adapter box
2
upwards out of the
bracket.
2. Fold open the adapter box
2
and remove the
necessary adapter:
Purposes of the pump head and the adapt-
ers (fig. C1)
SCHRADER (S/
)
2a
e.g. balls
2b
e.g. inflatable toys
2c
e.g. air mattresses
A
To pump up inner tubes with a Schrader valve,
e.g. mountain bike, transport carts or trailers.
DUNLOP / PRESTA (P/
)
B
To pump up inner tubes with a Dunlop valve,
e.g. for city/trekking bicycles.
C
To pump up inner tubes with a Presta valve, e.g.
for a racing bike and mountain bike.
(For locking, please flip the lever
3a
of the pump
head
3
downwards.)
(Valves
A
,
B
,
C
not included in the scope of de-
livery)
Pumping up tyres with a Schrader valve
: (fig. C2)
A
1. First, remove the dust cap.
2. Flip the lever
3a
upwards.
with the large opening (S/
3. Put the pump head
3
) on the valve.
4. To lock, flip the lever
3a
on the pump head
downwards.
If you are finished with pumping, flip the lever
upwards, remove the pump head
3
from the valve
and attach the dust cap.
Pumping up tyres with a Dunlop valve
(fig. C3)
1. First, remove the dust cap.
2. Flip the lever
3a
upwards.
3. Put the pump head
3
with the small opening (P/
) on the valve.
4. To lock, flip the lever
3a
on the pump head
downwards.
If you are finished with pumping, flip the lever
upwards, remove the pump head
3
from the valve
and attach the dust cap.
Pumping up tyres with a Presta valve
(fig. C4)
1. First, remove the dust cap.
2. Unscrew the nut of the valve (2.a—2.c).
3. Flip the lever
3a
upwards.
with the small opening (P/
4. Put the pump head
3
) on the valve.
5. To lock, flip the lever
3a
on the pump head
downwards.
If you are finished with pumping, flip the lever
3a
upwards, remove the pump head
valve, close the nut of the valve and attach the dust
cap.
Pumping up inflatable toys, air mattresses
etc. 2b/c: (fig. C5)
1. First, open the plug of the valve.
2. Flip the lever
3a
upwards.
3. Choose the appropriate adapter
2b/c
it into the large opening (S/
) of the pump
head
3
.
4. To lock, flip the lever on the
3a
pump head
downwards.
5. Now, insert the adapter
2b/c
into the item to be
inflated.
If you are finished with pumping, flip the lever
upwards, remove the pump head
3
from the valve
and close the plug of the valve.
Pumping up balls 2a: (fig. C6)
1. Flip the lever
3a
upwards.
2. For this, insert the adapter
2a
into the large open-
ing (S/
) of the pump head
3
.
3. To lock, flip the lever
3a
on the pump head
downwards.
3
NOTE!
3a
Moisten the adapter
2a
a little.
GB/IE/NI
B
:
3
3a
C
:
3
3
from the
and insert
3
3a
3
7