CONNECTION OF THE HOB FOR BIKB90
Land
Mains
230 V~
BE
50/60 Hz
400 V~
BE
50/60Hz
BE /
400 V~
NL
50/60Hz
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Caution! Be careful that the cables are correctly engaged and tightened.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Connection
Cable diameter
1 fase +N
3 x 4 mm
2 fasen + N
4 x 2,5 mm
3 fasen + N
5 x 1,5 mm
equipped with a faulty earth connection.
Cable
H 05 VV - F
2
H 05 RR - F
H 05 VV - F
2
H 05 RR - F
H 05 VV - F
2
H 05 RR - F
81
Protection
Wiring diagram
calibre
40 A *
25 A *
16 A *