Download Inhoudsopgave Inhoud Print deze pagina

Nieaf-Smitt NI 74 Handleiding pagina 55

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

Function
Frequency
(auto-ranging)
Sensitivity: >0.5 V RMS while ≤1 MHz
Sensitivity: >3 V RMS while >1 MHz
Input Protection:1000 VDC or 1000 VAC rms
Function
Duty cycle
Pulse width: >100 us, <100 ms
Frequency width: 5 Hz–150 kHz
Sensitivity: <0.5 V RMS
Overload protection: 1000 VDC or AC rms
Function
Temperature
Sensor: Type K thermocouple
Overload protection: 1000VDC or AC rms
Function
Diode test
Open circuit voltage: Max. 2 VDC
Overload protection: 1000 VDC or AC rms
Range
9.999 Hz
99.99 Hz
999.9 Hz
9.999 KHz
99.99 kHz
999.9 kHz
9.999 MHz
Range
0.1 % ~99.9 %
Range
-20
C...+400
C
o
o
400
C...1000
C
o
o
-4
F...+752
F
o
o
752
F...1832
F
o
o
Test current
0.3 mA typical
Resolution
0.0001 Hz
0.01 Hz
0.1 Hz
1 Hz
10 Hz
100 Hz
1 kHz
Resolution
0.1 %
Resolution
0.1
C
o
1
C
o
0.1
F
o
0.1
C
o
Resolution
1 mV
Accuracy
+ (1.2 % + 3 d)
+ (1.5 % + 4 d)
Accuracy
+ (1.2 % + 2 d)
Accuracy
+ (3.0 % + 5
C)
o
+ (3.0 % + 8
F)
o
Accuracy
+ (10 % + 5 d)
55
www.nieaf-smitt.com

Advertenties

Hoofdstukken

Inhoudsopgave
loading

Inhoudsopgave