5.2
MAX/MIN
Note: When using the MAX/MIN function in Autoranging mode, the
meter will "lock" into the range that is displayed on the LCD when
MAX/MIN is activated. If a MAX/Min reading exceeds that range, an
"OL" will be displayed. Select the desired range BEFORE entering
MAX/MIN mode.
1.
Press the MAX/MIN key to activate the MAX/MIN recording mode
2.
The display icon "MAX" will appear
3.
The meter will display and hold the maximum reading and will update
only when a new "max" occurs
4.
Press the MAX/MIN key again and the display icon "MIN" will appear.
5.
The meter will display and hold the minimum reading and will update only
when a new "min" occurs.
6.
To exit MAX/MIN mode press and hold the MAX/MIN key for 2 seconds
5.3
RELATIVE mode
The relative measurement feature allows you to make measurements relative
to a stored reference value. A reference voltage, current, etc. can be stored and
measurements made in comparison to that value. The displayed value is the
difference between the reference value and the measured value.
1.
Perform the measurement as described in the operating instructions
2.
Press the REL button to store the reading in the display and the "REL"
indicator will appear on the display
3.
The display will now indicate the difference between the stored value
and the measured value
4.
Press the REL button to exit the relative mode
Note: The Relative function does not operate in the Frequency
function.