NOTE: If your meter does not work properly, check the fuses and
batteries to make sure that they are still good and that they are
properly inserted.
6.2
Replacing fuses
WARNING: To avoid electric shock, disconnect the test leads from
any source of voltage before removing the fuse cover.
1.
Disconnect the test leads from the meter
2.
Remove the protective rubber holster
3.
Remove the battery cover (two "B" screws) and the battery
4.
Remove the six "A" screws securing the rear cover
5.
Gently remove the old fuse and install the new fuse into the holder
6.
Always use a fuse of the proper size and value (0.8 A/1000 V fast blow
for the 600 mA range [SIBA 70-172-40], 10 A/1000 V fast blow for the
20 A range [SIBA 50-199-06])
7.
Replace and secure the rear cover, battery and battery cover
WARNING: To avoid electric shock, do not operate your meter until
the fuse cover is in place and fastened securely.