Zekering van de smelter
V12
Slang/kop
2
4
200 V
46 A
62 A
3 Ph D
230 V
40 A
54 A
3 Ph D
400 V
21 A
29 A
3 Ph Y
400 V
21 A
29 A
3 Ph D
480 V
17 A
24 A
3 Ph D
V25, V25H
Slang/kop
2
4
200 V
56 A
72 A
3 Ph D
230 V
49 A
62 A
3 Ph D
400 V
27 A
35 A
3 Ph Y
400 V
27 A
35 A
3 Ph D
480 V
23 A
29 A
3 Ph D
E 2008 Nordson Corporation
Apparaattypes VB, VC, VW, VX
6
2
62 A
57 A
54 A
49 A
31 A
26 A
31 A
26 A
26 A
22 A
Apparaattypes VD, VE, VY, VZ
6
8
2
72 A
86 A
61 A
62 A
75 A
53 A
35 A
43 A
32 A
35 A
43 A
32 A
29 A
36 A
26 A
VersaBlue_NW_Siemens
V25, V25H
Slang/kop
4
6
72 A
72 A
62 A
62 A
33 A
34 A
33 A
34 A
28 A
28 A
V50, V50H
Slang/kop
4
6
8
76 A
79 A
90 A
66 A
68 A
83 A
34 A
41 A
49 A
34 A
41 A
49 A
28 A
34 A
41 A
Technische gegevens
V50, V50H
Slang/kop
2
4
6
61 A
76 A
78 A
53 A
66 A
66 A
30 A
38 A
46 A
30 A
38 A
46 A
25 A
32 A
38 A
V100, V10H
Slang/kop
2
4
6
90 A
90 A
90 A
78 A
90 A
90 A
43 A
49 A
51 A
43 A
49 A
51 A
36 A
41 A
43 A
P/N 7146505A
9-5
8
90 A
90 A
64 A
64 A
53 A